{"id":348,"date":"2016-02-25T00:16:27","date_gmt":"2016-02-25T00:16:27","guid":{"rendered":"http:\/\/www.edisontc.org\/ui\/?page_id=348"},"modified":"2017-03-09T22:13:10","modified_gmt":"2017-03-09T22:13:10","slug":"electrostatic-voltmeters-and-field-meters","status":"publish","type":"page","link":"http:\/\/www.edisontc.org\/ui\/home\/course\/unit-i\/electrostatic-voltmeters-and-field-meters\/","title":{"rendered":"Electrostatic Voltmeters and Field Meters"},"content":{"rendered":"<p>This type of meter was developed in the 1880s and was an alternative to magnetic coil meters. The idea is that we can charge two plates which become attracted to one another when in proximity or direct contact to high voltage. If we place a spring or weight to keep the plates apart by default the forces will work against that to pull the plates together.<\/p>\n<p>A great thing about electrostatic meters is that they could be used to effectively measure AC power, you would not have to rectify (convert to DC) the signal like you do if you use at magnetic coil meter.<a name=\"static\"><\/a><\/p>\n<p><b>Electrostatic Voltmeters:<\/b><br \/>\nThis device measures the actual potential at an object&#8217;s surface. Some electrostatic voltmeters have a &#8220;butterfly&#8221; look and are used to measure hundreds to thousands of volts.<a name=\"static\"><\/a><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-350 aligncenter\" src=\"http:\/\/www.edisontc.org\/ui\/files\/2016\/02\/StanleyGroundDetector600-1-300x290.jpg\" alt=\"StanleyGroundDetector600\" width=\"300\" height=\"290\" srcset=\"http:\/\/www.edisontc.org\/ui\/files\/2016\/02\/StanleyGroundDetector600-1-300x290.jpg 300w, http:\/\/www.edisontc.org\/ui\/files\/2016\/02\/StanleyGroundDetector600-1.jpg 600w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<p>Above: This electrostatic meter detects charge and is used in grounding high voltage circuits. This meter was designed by William Stanley in 1896. Today you&#8217;ll find <a href=\"https:\/\/books.google.com\/books?id=UZpPAAAAMAAJ&amp;pg=PA717&amp;lpg=PA717&amp;dq=electrostatic+ground+detectors&amp;source=bl&amp;ots=HQr71o1v6C&amp;sig=i0AfUjRqJ4EEneIJpfUDU8qg8OY&amp;hl=en&amp;sa=X&amp;ved=0ahUKEwjk-Zj_iqPLAhUC4CYKHUhNAIYQ6AEIMDAA#v=onepage&amp;q=electrostatic%20ground%20detectors&amp;f=false\">electrostatic ground detectors<\/a> used to make sure fuel tanker trucks are grounded properly so that there will not be a spark that could cause an explosion during loading and unloading the product. AC systems also have to be properly grounded for safety.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-872 size-full aligncenter\" src=\"http:\/\/www.edisontc.org\/ui\/files\/2016\/02\/ElectrostaticMeterGraphic-3-500.jpg\" alt=\"ElectrostaticMeterGraphic-3-500\" width=\"500\" height=\"273\" srcset=\"http:\/\/www.edisontc.org\/ui\/files\/2016\/02\/ElectrostaticMeterGraphic-3-500.jpg 500w, http:\/\/www.edisontc.org\/ui\/files\/2016\/02\/ElectrostaticMeterGraphic-3-500-300x164.jpg 300w, http:\/\/www.edisontc.org\/ui\/files\/2016\/02\/ElectrostaticMeterGraphic-3-500-24x13.jpg 24w, http:\/\/www.edisontc.org\/ui\/files\/2016\/02\/ElectrostaticMeterGraphic-3-500-36x20.jpg 36w, http:\/\/www.edisontc.org\/ui\/files\/2016\/02\/ElectrostaticMeterGraphic-3-500-48x26.jpg 48w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/p>\n<p><b>How it works: <\/b>With the rotational configuration above one of the plates (which is aluminum or carbon) is allowed to rotate and wants to align itself with the other plate. Either the meter sits and uses gravity to zero the needle, or a spring pushes the rotating plate so that is zeroed. A spring system allows the meter to not have to sit vertically. <a href=\"https:\/\/youtu.be\/hlCHpkkmBdo\">See our video<\/a>.<\/p>\n<p><strong>Electrostatic field meters<\/strong> will measure the electrostatic field at some distance from the meter&#8217;s actual sensors. More on <a href=\"https:\/\/en.wikipedia.org\/wiki\/Electrostatic_fieldmeter\">electrostatic field meters.<\/a><\/p>\n<p>In our next page we will talk about how we measure high voltage today using PTs (Potential Transformers) and CTs (Current Transformers).<\/p>\n<table width=\"100%\">\n<tbody>\n<tr>\n<td>\n<div style=\"background: grey; float: left; text-align: center; line-height: 100px; width: 40%; margin: 10px; padding: 10px; box-shadow: 5px 5px 10px #000; min-height: 100px;\"><a style=\"text-decoration: none;\" href=\"http:\/\/www.edisontc.org\/ui\/home\/course\/unit-i\/measuring-high-voltage\/\">Back<\/a><\/div>\n<div style=\"background: grey; float: right; text-align: center; line-height: 100px; width: 40%; margin: 10px; padding: 10px; box-shadow: 5px 5px 10px #000; min-height: 100px;\"><a style=\"text-decoration: none;\" href=\"http:\/\/www.edisontc.org\/ui\/home\/course\/unit-i\/cts-and-pts\/\">Next<\/a><\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Sources are found on our <a href=\"http:\/\/www.edisontc.org\/ui\/credits\/\">credits page<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>This type of meter was developed in the 1880s and was an alternative to magnetic coil meters. The idea is that we can charge two plates which become attracted to one another when in proximity or direct contact to high voltage. If we place a spring or weight to keep the plates apart by default &hellip; <a href=\"http:\/\/www.edisontc.org\/ui\/home\/course\/unit-i\/electrostatic-voltmeters-and-field-meters\/\" class=\"more-link\">Continue reading <span class=\"screen-reader-text\">Electrostatic Voltmeters and Field Meters<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":694,"parent":9,"menu_order":8,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-348","page","type-page","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v19.10 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Electrostatic Voltmeters and Field Meters - Universe of Instrumentation<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"http:\/\/www.edisontc.org\/ui\/home\/course\/unit-i\/electrostatic-voltmeters-and-field-meters\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Electrostatic Voltmeters and Field Meters - Universe of Instrumentation\" \/>\n<meta property=\"og:description\" content=\"This type of meter was developed in the 1880s and was an alternative to magnetic coil meters. The idea is that we can charge two plates which become attracted to one another when in proximity or direct contact to high voltage. If we place a spring or weight to keep the plates apart by default &hellip; Continue reading Electrostatic Voltmeters and Field Meters\" \/>\n<meta property=\"og:url\" content=\"http:\/\/www.edisontc.org\/ui\/home\/course\/unit-i\/electrostatic-voltmeters-and-field-meters\/\" \/>\n<meta property=\"og:site_name\" content=\"Universe of Instrumentation\" \/>\n<meta property=\"article:modified_time\" content=\"2017-03-09T22:13:10+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/www.edisontc.org\/ui\/files\/2016\/02\/Unit1Banner900-1a.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"254\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"http:\/\/www.edisontc.org\/ui\/home\/course\/unit-i\/electrostatic-voltmeters-and-field-meters\/\",\"url\":\"http:\/\/www.edisontc.org\/ui\/home\/course\/unit-i\/electrostatic-voltmeters-and-field-meters\/\",\"name\":\"Electrostatic Voltmeters and Field Meters - Universe of Instrumentation\",\"isPartOf\":{\"@id\":\"http:\/\/www.edisontc.org\/ui\/#website\"},\"datePublished\":\"2016-02-25T00:16:27+00:00\",\"dateModified\":\"2017-03-09T22:13:10+00:00\",\"breadcrumb\":{\"@id\":\"http:\/\/www.edisontc.org\/ui\/home\/course\/unit-i\/electrostatic-voltmeters-and-field-meters\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"http:\/\/www.edisontc.org\/ui\/home\/course\/unit-i\/electrostatic-voltmeters-and-field-meters\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"http:\/\/www.edisontc.org\/ui\/home\/course\/unit-i\/electrostatic-voltmeters-and-field-meters\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"http:\/\/www.edisontc.org\/ui\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Home\",\"item\":\"http:\/\/www.edisontc.org\/ui\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Course\",\"item\":\"http:\/\/www.edisontc.org\/ui\/home\/course\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Unit I Measuring Electricity\",\"item\":\"http:\/\/www.edisontc.org\/ui\/home\/course\/unit-i\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"Electrostatic Voltmeters and Field Meters\"}]},{\"@type\":\"WebSite\",\"@id\":\"http:\/\/www.edisontc.org\/ui\/#website\",\"url\":\"http:\/\/www.edisontc.org\/ui\/\",\"name\":\"Universe of Instrumentation\",\"description\":\"Engineering tools and instruments\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"http:\/\/www.edisontc.org\/ui\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Electrostatic Voltmeters and Field Meters - Universe of Instrumentation","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"http:\/\/www.edisontc.org\/ui\/home\/course\/unit-i\/electrostatic-voltmeters-and-field-meters\/","og_locale":"en_US","og_type":"article","og_title":"Electrostatic Voltmeters and Field Meters - Universe of Instrumentation","og_description":"This type of meter was developed in the 1880s and was an alternative to magnetic coil meters. The idea is that we can charge two plates which become attracted to one another when in proximity or direct contact to high voltage. If we place a spring or weight to keep the plates apart by default &hellip; Continue reading Electrostatic Voltmeters and Field Meters","og_url":"http:\/\/www.edisontc.org\/ui\/home\/course\/unit-i\/electrostatic-voltmeters-and-field-meters\/","og_site_name":"Universe of Instrumentation","article_modified_time":"2017-03-09T22:13:10+00:00","og_image":[{"width":800,"height":254,"url":"http:\/\/www.edisontc.org\/ui\/files\/2016\/02\/Unit1Banner900-1a.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"http:\/\/www.edisontc.org\/ui\/home\/course\/unit-i\/electrostatic-voltmeters-and-field-meters\/","url":"http:\/\/www.edisontc.org\/ui\/home\/course\/unit-i\/electrostatic-voltmeters-and-field-meters\/","name":"Electrostatic Voltmeters and Field Meters - Universe of Instrumentation","isPartOf":{"@id":"http:\/\/www.edisontc.org\/ui\/#website"},"datePublished":"2016-02-25T00:16:27+00:00","dateModified":"2017-03-09T22:13:10+00:00","breadcrumb":{"@id":"http:\/\/www.edisontc.org\/ui\/home\/course\/unit-i\/electrostatic-voltmeters-and-field-meters\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["http:\/\/www.edisontc.org\/ui\/home\/course\/unit-i\/electrostatic-voltmeters-and-field-meters\/"]}]},{"@type":"BreadcrumbList","@id":"http:\/\/www.edisontc.org\/ui\/home\/course\/unit-i\/electrostatic-voltmeters-and-field-meters\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"http:\/\/www.edisontc.org\/ui\/"},{"@type":"ListItem","position":2,"name":"Home","item":"http:\/\/www.edisontc.org\/ui\/"},{"@type":"ListItem","position":3,"name":"Course","item":"http:\/\/www.edisontc.org\/ui\/home\/course\/"},{"@type":"ListItem","position":4,"name":"Unit I Measuring Electricity","item":"http:\/\/www.edisontc.org\/ui\/home\/course\/unit-i\/"},{"@type":"ListItem","position":5,"name":"Electrostatic Voltmeters and Field Meters"}]},{"@type":"WebSite","@id":"http:\/\/www.edisontc.org\/ui\/#website","url":"http:\/\/www.edisontc.org\/ui\/","name":"Universe of Instrumentation","description":"Engineering tools and instruments","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"http:\/\/www.edisontc.org\/ui\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"http:\/\/www.edisontc.org\/ui\/wp-json\/wp\/v2\/pages\/348","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.edisontc.org\/ui\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/www.edisontc.org\/ui\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/www.edisontc.org\/ui\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.edisontc.org\/ui\/wp-json\/wp\/v2\/comments?post=348"}],"version-history":[{"count":13,"href":"http:\/\/www.edisontc.org\/ui\/wp-json\/wp\/v2\/pages\/348\/revisions"}],"predecessor-version":[{"id":873,"href":"http:\/\/www.edisontc.org\/ui\/wp-json\/wp\/v2\/pages\/348\/revisions\/873"}],"up":[{"embeddable":true,"href":"http:\/\/www.edisontc.org\/ui\/wp-json\/wp\/v2\/pages\/9"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.edisontc.org\/ui\/wp-json\/wp\/v2\/media\/694"}],"wp:attachment":[{"href":"http:\/\/www.edisontc.org\/ui\/wp-json\/wp\/v2\/media?parent=348"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}